Engineer Reset (After an Alarm)
If the Reset Mode(s) has been programmed for Engineer follow the steps below to reset the
system.
1) The user must first unset the system. Details in User manual.
2) With the display showing:-
Enter the Engineer code followed by Yes ( ).
3) The exit tone will sound and the display will show:-
4) Enter the Engineer code again to abort the setting.
It should be noted that if the Tamper reset has been programmed for Engineer Reset the
display will show:-
for 10 seconds each time the user attempts to set the system. The procedure as shown
above is used to Reset this condition.
Anti-Code Reset (After Alarm or Service
Timer Lockout)
To effect an Anti-Code Reset the engineer will require either a Anti-Code Generator or
Anti-Code Software running on a P.C.
1) Ask the customer to enter the user code and then press Yes ( ).
2) A four digit seed code will be shown by the display.
3) Enter this seed code into either the Generator or P.C. Software. An Anti-Code will be
given.
4) Ask the customer to enter this Anti-Code. The system is now reset.
Note: Service Timer Lockout will have been indicated to the user. Two weeks notice would have
been given prior to Lockout. Resetting this via Anti-Code will give another two weeks service. A
service visit should be arranged and the Service Timer should be re-programmed to the
required number of weeks.
! ! Service Due !
! ! ! ! CHECK ! !!!!
Exit Now ! . . .
Ok !
GardTec 480 ENG PR5832 Rev 115IN480IM B A5booklet.qxd 18/07/2007 20:35 Page 18